Request to included calibration information in CAL_PSF_MAG and FITS header of diff.cmf files
| Reported by: | Michael Wood-Vasey | Owned by: | Paul Price |
|---|---|---|---|
| Priority: | normal | Milestone: | |
| Component: | ppSub | Version: | current |
| Severity: | normal | Keywords: | |
| Cc: |
Description
It would be very helpful to the TCS, and likely users in general, if CAL_PSF_MAG were set in diff.cmf files and the zeropoint calibration could also be included in the FITS header of the diff .cmf files. Currently I understand the zeropoint in the database, but it would be very convenient to have it in the FITS header and the CAL_PSF_MAG values of the .cmf file. This would both be easier and make it less likely that someone would use the wrong value because they looked up the ref zeropoint rather than the in zeropoint.
Paul and I chatted about this yesterday, I just wanted to add it into the bug tracker system.

Should be working as of trunk@26964.