Message:

TIMESYS is supposed to be STR in camera format file.

File:
1 edited

Legend:

Unmodified
Added
Removed
  • trunk/psModules/src/config/pmConfigCamera.c

    r23451 r23452  
    332332        psMetadataAddS32(defaults, PS_LIST_TAIL, "CHIP.X0", 0, NULL, 0);
    333333        psMetadataAddS32(defaults, PS_LIST_TAIL, "CELL.READDIR", 0, "Read direction (rows)", 1);
    334         psMetadataAddS32(defaults, PS_LIST_TAIL, "CELL.TIMESYS", 0, "Time system", PS_TIME_TAI);
    335         psMetadataAddS32(defaults, PS_LIST_TAIL, "FPA.TIMESYS", 0, "Time system", PS_TIME_TAI);
     334        psMetadataAddStr(defaults, PS_LIST_TAIL, "CELL.TIMESYS", 0, "Time system", "TAI");
     335        psMetadataAddStr(defaults, PS_LIST_TAIL, "FPA.TIMESYS", 0, "Time system", "TAI");
    336336
    337337        psMetadataAddMetadata(format, PS_LIST_TAIL, "DEFAULTS", 0, "Default values for concepts", defaults);