| Version 4 (modified by , 16 years ago) ( diff ) |
|---|
difference image concerns:
- normalizations:
- are they correct?
- significant coupling between normalization and other kernel terms
- ringing -- there is significant ringing left behind in difference of images with PS1_V1 PSF shapes
- is the basis function able to represent the actual observed differences sufficiently?
- is the observed ringing the result of the coupling to the normalization?
- is the observed ringing due to the degeneracy between basis terms?
- basis function orthogonality
- does the non-orthogonal nature of the Alard-Lupton kernels increase sensitivity to noise and false positives?
- can we choose a more-orthogonal basis set?
- span of basis set
- how can we choose a set of kernels that spans a sufficient range?
- can the Alard-Lupton basis set cover a wide enough range of structures?
- weighting?
- windowing?
- dual convolution -- strange results with power going to non-radial terms
Some specific bugs identified
- normalizations were failing for 1D convolutions
- the wrong preCalc element was being used in a certain context related to Dual
- the peak pixel is rediscovered, changing the center by 1 pixel for well-centered stars (this is not technically a bug, but makes it difficult to interpret the chi-square images)