* Controller ID: 1 PD Reset: PD = --:--:12, Error = 3, Path = 50:00:62:b2:00:02:d9:98 REPLACED * Controller ID: 0 Command timeout on PD: PD = --:--:13 REPLACED * 9/21/2012 replaced disk #2 on controller #1 - rebuild started normally * 09-25-2012 Controller ID: 1 PD Reset: PD = --:--:3, Error = 3 (after 10 of these, replaced the drive). * 09-29-2012T01:53:14 2012 Controller ID: 1 PD Reset: PD = --:--:20, Error = 3, Path = 50:00:62:b2:00:02:d9:9c (replaced the drive, but had to reboot the machine to get the controller card to come back online) * Wed Feb 20 21:45:25 2013 Controller ID: 1 Command timeout on PD: PD = --:--:17 - No addtional sense information, CDB = 0x28 0x00 0xc4 0xc1 0x08 0x00 0x00 0x08 0x00 0x00 , Sense = 50:00:62:b2:00:02:d9:89, Path = (replaced 02/21/2013) * 03-09-13 Controller ID: 2 Command timeout on PD: PD = --:--:23 - No addtional sense information, CDB = 0x28 0x00 0xad 0x96 0x78 0x00 0x00 0x08 0x00 0x00 , Sense = 50:00:62:b2:00:02:72:1f, Path = Generated on:Sat Mar 9 20:17:16 2013. Disk swapped on 3/10/13 * Tue Sep 3 05:31:36 2013 Controller ID: 0 Error: --:--:3 (Error 2) (replaced 09/03/13)