    248248 * 11:10 MEH: even with no jobs running, the WS query has continued to timeout and 12 long queries trying to run -- mysqld.slow.log shows >600s to 6ks (pantasks timeout=600, so tweak to 1800)
    249249 * 12:45 MEH: long WS query runs in 30s or less on ippdb03,db05.. something wrong with db01, even w/ all stop but stdlanl..
    250   * raise timeout to 3600s --
     250  * raise timeout to 3600s -- 3pi query timeout..
     251 * 15:45 MEH: we have power cycle access now for ipp082-087 on console
     252 * 16:00 MEH: looks like battery relearn may have worked on the newer data nodes, but still retains WT policy?
     253{{{
     254Dec  7 01:40:47 ipp083 MR_MONITOR[16550]: <MRMON194> Controller ID:  0   BBU enabled; changing WT logical drives to WB
     255Dec  7 01:40:47 ipp083 MR_MONITOR[16550]: <MRMON054> Controller ID:  0   Policy change on VD:   0
     256Dec  7 01:40:47 ipp083 Current   =   Current Write Policy: Write Through;
     257}}}
     258  * ipp084,087 not have this message -- relearn not finished?