IPP Software Navigation Tools IPP Links Communication Pan-STARRS Links

Changeset 10987


Ignore:
Timestamp:
Jan 8, 2007, 3:59:54 PM (19 years ago)
Author:
jhoblitt
Message:

add comment about S8 vs. bool in the database

File:
1 edited

Legend:

Unmodified
Added
Removed
  • trunk/psLib/src/db/psDB.c

    r10986 r10987  
    1212 *  @author Joshua Hoblitt
    1313 *
    14  *  @version $Revision: 1.129 $ $Name: not supported by cvs2svn $
    15  *  @date $Date: 2007-01-09 01:53:49 $
     14 *  @version $Revision: 1.130 $ $Name: not supported by cvs2svn $
     15 *  @date $Date: 2007-01-09 01:59:54 $
    1616 *
    1717 *  Copyright (C) 2005-2006  Joshua Hoblitt, University of Hawaii
     
    21922192        psDBAddToLookupTable(pTypeToSQLlookupTable, PS_TYPE_C32, "PS_TYPE_C32 is not supported");
    21932193        psDBAddToLookupTable(pTypeToSQLlookupTable, PS_TYPE_C64, "PS_TYPE_C64 is not supported");
     2194        // XXX Since BOOL is added after S8 all "TINYINT" data will appear in
     2195        // the database as boolean data.  There does not seem to be any way to
     2196        // work around this with MySQL < 5.0.3.
    21942197        psDBAddToLookupTable(pTypeToSQLlookupTable, PS_DATA_BOOL,"TINYINT");
    21952198        psDBAddToLookupTable(pTypeToSQLlookupTable, PS_DATA_STRING, "VARCHAR");